$ EZ-EDS Version 3.27.1.20191218 Generated Electronic Data Sheet [File] DescText = "Lenze i550 Inverter Drive with Cyc10"; CreateDate = 03-13-2015; CreateTime = 17:32:43; ModDate = 03-10-2020; ModTime = 11:12:09; Revision = 1.5; [Device] VendCode = 587; VendName = "Lenze"; ProdType = 2; ProdTypeStr = "AC Drive Device"; ProdCode = 550; MajRev = 4; MinRev = 2; ProdName = "IOFW51AG4X"; Catalog = "2020-03-10-i550-Cyc10"; Icon = "Lenze.ico"; IconContents = "AAABAAEAICAEAAAAAADoAgAAFgAAACgAAAAgAAAAQAAAAAEABAAAAAAAAAIA" "AAAAAAAAAAAAAAAAAAAAAAAAAAAAAACAAACAAAAAgIAAgAAAAIAAgACAgAAA" "wMDAAICAgAAAAP8AAP8AAAD//wD/AAAA/wD/AP//AAD///8AzMDMwAwADAzM" "wAzMAAAAAMAAwAAMAMwMwAAMAAAAAADAAMzADAzMAMwADMwAAAAAwADAAAzM" "DAAMwAwAAAAAAMAAzMAMwAwMzMAMzAAAAAAAAAAAAAAAjwAAAAAAAAAAAAAA" "AAAAAI93d3d3d4AAAAAAAAAAAACPd3d3d3eIAAAAAAAAAAAAj3d3d3d3iIAA" "AAAAAAAAAI93d3d3d4iIAAAAAAAAAACPd3d3d3eIiAAAAAAAAAAAj3d3d3d3" "iIgAAAAAAAAAAI93d3d3d4iIAAAAAAAAAACPd3d3d3eIiAAAAAAAAAAAj3d3" "d3d3iIgACIiIiIiIAI93d3d3d4iIAAiIh3eIiACPd3d3d3eIiAAACId3iAAA" "j3d3d3d3iIgAAId3d3eAAI93d3d3d4iIAACHcIh3gACPd3d3d3eIiAAIdwAH" "h3gHj3AAAAAHiIgACHeAAId4B49wAAAAB4iIAAh3hweHeAePcAAAAAeIiAAA" "h3iId4AAj3AAAAAHiIgAAId3d3eAAI9wAAAAB4iIAAAIh3eIAACPd3d3d3eI" "iAAAAAiIAAAAj///////iIgAAAAAAAAAAAh3d3d3d4iIAAAAAAAAAAAAh3d3" "d3d4iAAAAAAAAAAAAAh3d3d3d4gAAAAAAAAAAAAAh3d3d3d4AAAAAAAAAAAA" "AAiIiIiIiAARuhj/d7J7/3GjOP93i5v/cZoY///8AB///AAP//wAB//8AAP/" "/AAB//wAAf/8AAH//AAB//wAAcAEAAGABAABgAQAAeAMAAHABAABwAQAAYAA" "AAGAAAABgAAAAcAEAAHABAAB4AwAAfgcAAH//gAB//8AAf//gAH//8AB///g" "AQ=="; [Device Classification] Class1 = EtherNetIP; [Params] Param1 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "SINT_INP", $ name "", $ units "(8bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param2 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "INT_INP", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param3 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "DINT_INP", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param4 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2B0B/0 Freq Setpoint Hz", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param5 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2D40/4 Device Load Act.", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param6 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2D4F/0 Motor i2t utiliz.", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param7 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2D82/0 Motor voltage", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param8 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2D88/0 Motor current", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param9 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2DA2/1 Effective Power", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param10 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2DA2/2 Apparent Power",$ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param11 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2DA3/1 Energy Out Motor", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param12 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2DA3/2 Energy Out Gen.", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param13 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA4/1 Anlg In1 %", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param14 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA4/2 Anlg In1 Freq", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param15 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA4/3 Anlg In1 PidVal", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param16 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA4/4 Anlg In1 TorqVal", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param17 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA5/1 Anlg In2 %", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param18 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA5/2 Anlg In2 Freq", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param19 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA5/3 Anlg In2 PidVal", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param20 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DA5/4 Anlg In2 TorqVal", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param21 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DAA/1 AO1 Value (VDC)", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param22 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DAA/2 AO1 Value (IDC)", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param23 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "reserved23", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param24 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2DD3/1 Speed set", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param25 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "reserved25", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param26 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "2DDD/0 Actual Frequency", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param27 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400A/1 NetWordOUT1", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param28 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400A/2 NetWordOUT2", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param29 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/1 AC Drv Stat Word", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param30 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/2 C0150 Stat Word", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param31 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/3 Actual Speed Hz", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param32 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/4 Actual Speed RPM", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param33 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/5 Drive State", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param34 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/6 Act Speed 0.01Hz", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param35 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/7 Actual Torque Scaled", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param36 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400D/0 Scaled Speed", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param37 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "401F/1 Actual PID Stpnt", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param38 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "401F/2 Actual PID Fbk",$ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param39 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "401F/3 PID bits", $ name "", $ units "(8bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param40 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "603F/0 Current Fault", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param41 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6041/0 Status Word", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param42 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6043/0 Veloc Demand", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param43 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6044/0 Veloc Actual", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param44 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "6061/0 402 Mode Display", $ name "", $ units "(8bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param45 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6077/0 402 ActualTorq %", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param46 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6078/0 402 ActualCur %", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param47 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "6079/0 402 DClink Volt", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param48 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "60FD/0 Dig Inputs Stat", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param50 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400C/9 Proc Output Freq", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param51 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "SINT_OUT", $ name "", $ units "(8bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param52 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "INT_OUT", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param53 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "DINT_OUT", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param54 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2946/1 Trq Mode Hi Spd", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param55 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "2946/2 Trq Mode Lo Spd", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param56 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "4008/1 NetWordIN1", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param57 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "4008/2 NetWordIN2", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param58 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "4008/3 NetWordIN3", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param59 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "4008/4 NetWordIN4", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param60 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/1 AC Drv Ctrl Word", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param61 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/2 C0135 Ctrl Word", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param62 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/3 Net Spd Stpnt Hz", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param63 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/4 Net Spd Stpnt RPM", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param64 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/5 Net Spd 0.01 Hz", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param65 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/6 NetSpdSign 0.1Hz", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param66 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/7 Net PID Stpnt", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param67 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/8 Net Torque Stpnt", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param68 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6040/0 Control Word", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param69 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6042/0 Target Veloc", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param70 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "6046/1 Veloc Min", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param71 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "6046/2 Veloc Max", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param72 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "6048/1 Delta Speed", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param73 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6048/2 Delta Time", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param74 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "6049/1 Delta Speed", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param75 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6049/2 Delta Time", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param76 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "6060/0 402 Control Modes", $ name "", $ units "(8bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param77 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "6071/0 402 TargetTorq",$ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param78 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "6080/0 Mot Max Speed", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param79 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "60E0/0 Pos TorqLimit", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param80 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "60E1/0 Neg TorqLimit", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param82 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC3, $ Data Type 2, $ Data Size in bytes "400B/13 Proc Input Freq", $ name "", $ units "(16bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param100 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "Trailer Input", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param101 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC4, $ Data Type 4, $ Data Size in bytes "Trailer Output", $ name "", $ units "(32bit)", $ help string ,,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param1000 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0002, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "OUT Ctrl1:", $ name "", $ units "New Help String", $ help string 0x14,0x15,0x15, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum1000 = 0x14,"Basic", 0x15,"Extended"; Param1001 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0002, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "INP Ctrl1:", $ name "", $ units "New Help String", $ help string 0x46,0x47,0x47, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum1001 = 0x46,"Basic", 0x47,"Extended"; Param1002 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0002, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "OUT Ctrl2:", $ name "", $ units "New Help String", $ help string 0x16,0x17,0x17, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum1002 = 0x16,"Basic", 0x17,"Extended"; Param1003 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0002, $ Descriptor 0xC2, $ Data Type 1, $ Data Size in bytes "INP Ctrl2:", $ name "", $ units "New Help String", $ help string 0x48,0x49,0x49, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum1003 = 0x48,"Basic", 0x49,"Extended"; Param2000 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0000, $ Descriptor 0xC8, $ Data Type 4, $ Data Size in bytes "RPI Value", $ name "", $ units "", $ help string 4000,100000,10000, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param34000000 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#1", $ name "", $ units "", $ help string 0,65535,29, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000000 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000001 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#2", $ name "", $ units "", $ help string 0,65535,32, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000001 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000002 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#3", $ name "", $ units "", $ help string 0,65535,35, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000002 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000003 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#4", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000003 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000004 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#5", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000004 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000005 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#6", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000005 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000006 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#7", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000006 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000007 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#8", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000007 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000008 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#9", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000008 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000009 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#10", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000009 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000010 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#11", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000010 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000011 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#12", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000011 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000012 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#13", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000012 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000013 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#14", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000013 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000014 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#15", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000014 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000015 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Input#16", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000015 = 0,"ignore", 1,"SINT_INP", 2,"INT_INP", 3,"DINT_INP", 4,"2B0B/0 Freq Setpoint Hz", 5,"2D40/4 Device Load Act.", 6,"2D4F/0 Motor i2t utiliz.", 7,"2D82/0 Motor voltage", 8,"2D88/0 Motor current", 9,"2DA2/1 Effective Power", 10,"2DA2/2 Apparent Power", 11,"2DA3/1 Energy Out Motor", 12,"2DA3/2 Energy Out Gen.", 13,"2DA4/1 Anlg In1 %", 14,"2DA4/2 Anlg In1 Freq", 15,"2DA4/3 Anlg In1 PidVal", 16,"2DA4/4 Anlg In1 TorqVal", 17,"2DA5/1 Anlg In2 %", 18,"2DA5/2 Anlg In2 Freq", 19,"2DA5/3 Anlg In2 PidVal", 20,"2DA5/4 Anlg In2 TorqVal", 21,"2DAA/1 AO1 Value (VDC)", 22,"2DAA/2 AO1 Value (IDC)", 23,"reserved23", 24,"2DD3/1 Speed set", 25,"reserved25", 26,"2DDD/0 Actual Frequency", 27,"400A/1 NetWordOUT1", 28,"400A/2 NetWordOUT2", 29,"400C/1 AC Drv Stat Word", 30,"400C/2 C0150 Stat Word", 31,"400C/3 Actual Speed Hz", 32,"400C/4 Actual Speed RPM", 33,"400C/5 Drive State", 34,"400C/6 Act Speed 0.01Hz", 35,"400C/7 Actual Torque Scaled", 36,"400D/0 Scaled Speed", 37,"401F/1 Actual PID Stpnt", 38,"401F/2 Actual PID Fbk", 39,"401F/3 PID bits", 40,"603F/0 Current Fault", 41,"6041/0 Status Word", 42,"6043/0 Veloc Demand", 43,"6044/0 Veloc Actual", 44,"6061/0 402 Mode Display", 45,"6077/0 402 ActualTorq %", 46,"6078/0 402 ActualCur %", 47,"6079/0 402 DClink Volt", 48,"60FD/0 Dig Inputs Stat", 50,"400C/9 Proc Output Freq"; Param34000050 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#1", $ name "", $ units "", $ help string 0,65535,60, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000050 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000051 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#2", $ name "", $ units "", $ help string 0,65535,63, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000051 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000052 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#3", $ name "", $ units "", $ help string 0,65535,67, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000052 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000053 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#4", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000053 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000054 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#5", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000054 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000055 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#6", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000055 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000056 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#7", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000056 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000057 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#8", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000057 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000058 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#9", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000058 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000059 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#10", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000059 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000060 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#11", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000060 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000061 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#12", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000061 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000062 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#13", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000062 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000063 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#14", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000063 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000064 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#15", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000064 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000065 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Custom Output#16", $ name "", $ units "", $ help string 0,65535,0, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000065 = 0,"ignore", 51,"SINT_OUT", 52,"INT_OUT", 53,"DINT_OUT", 54,"2946/1 Trq Mode Hi Spd", 55,"2946/2 Trq Mode Lo Spd", 56,"4008/1 NetWordIN1", 57,"4008/2 NetWordIN2", 58,"4008/3 NetWordIN3", 59,"4008/4 NetWordIN4", 60,"400B/1 AC Drv Ctrl Word", 61,"400B/2 C0135 Ctrl Word", 62,"400B/3 Net Spd Stpnt Hz", 63,"400B/4 Net Spd Stpnt RPM", 64,"400B/5 Net Spd 0.01 Hz", 65,"400B/6 NetSpdSign 0.1Hz", 66,"400B/7 Net PID Stpnt", 67,"400B/8 Net Torque Stpnt", 68,"6040/0 Control Word", 69,"6042/0 Target Veloc", 70,"6046/1 Veloc Min", 71,"6046/2 Veloc Max", 72,"6048/1 Delta Speed", 73,"6048/2 Delta Time", 74,"6049/1 Delta Speed", 75,"6049/2 Delta Time", 76,"6060/0 402 Control Modes", 77,"6071/0 402 TargetTorq", 78,"6080/0 Mot Max Speed", 79,"60E0/0 Pos TorqLimit", 80,"60E1/0 Neg TorqLimit", 82,"400B/13 Proc Input Freq"; Param34000100 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Input Trailer", $ name "", $ units "", $ help string 100,100,100, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param34000101 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Output Trailer", $ name "", $ units "", $ help string 101,101,101, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Param34000200 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Input#1", $ name "", $ units "", $ help string 29,29,29, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000200 = 29,"400C/1 AC Drv Stat Word"; Param34000201 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Input#2", $ name "", $ units "", $ help string 32,32,32, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000201 = 32,"400C/4 Actual Speed RPM"; Param34000202 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Input#3", $ name "", $ units "", $ help string 35,35,35, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000202 = 35,"400C/7 Actual Torque Scaled"; Param34000250 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Output#1", $ name "", $ units "", $ help string 60,60,60, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000250 = 60,"400B/1 AC Drv Ctrl Word"; Param34000251 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Output#2", $ name "", $ units "", $ help string 63,63,63, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000251 = 63,"400B/4 Net Spd Stpnt RPM"; Param34000252 = 0, $ reserved, shall equal 0 ,, $ Link Path Size, Link Path 0x0400, $ Descriptor 0xC7, $ Data Type 2, $ Data Size in bytes "Output#3", $ name "", $ units "", $ help string 67,67,67, $ min, max, default data values ,,,, $ mult, div, base, offset scaling ,,,, $ mult, div, base, offset links ; $ decimal places Enum34000252 = 67,"400B/8 Net Torque Stpnt"; [Assembly] Object_Name = "Assembly Object"; Object_Class_Code = 0x04; Assem1 = "Input Assembly", , , 0x0000, ,, ,Param34000000, ,Param34000001, ,Param34000002, ,Param34000003, ,Param34000004, ,Param34000005, ,Param34000006, ,Param34000007, ,Param34000008, ,Param34000009, ,Param34000010, ,Param34000011, ,Param34000012, ,Param34000013, ,Param34000014, ,Param34000015, 32,Param34000100; Assem2 = "Output Assembly", , , 0x0000, ,, ,Param34000050, ,Param34000051, ,Param34000052, ,Param34000053, ,Param34000054, ,Param34000055, ,Param34000056, ,Param34000057, ,Param34000058, ,Param34000059, ,Param34000060, ,Param34000061, ,Param34000062, ,Param34000063, ,Param34000064, ,Param34000065, 32,Param34000101; Assem3 = "Config Assembly", , , 0x0800, ,, 16,Param34000000, 16,Param34000001, 16,Param34000002, 16,Param34000003, 16,Param34000004, 16,Param34000005, 16,Param34000006, 16,Param34000007, 16,Param34000008, 16,Param34000009, 16,Param34000010, 16,Param34000011, 16,Param34000012, 16,Param34000013, 16,Param34000014, 16,Param34000015, 16,Param34000100, 16,Param34000050, 16,Param34000051, 16,Param34000052, 16,Param34000053, 16,Param34000054, 16,Param34000055, 16,Param34000056, 16,Param34000057, 16,Param34000058, 16,Param34000059, 16,Param34000060, 16,Param34000061, 16,Param34000062, 16,Param34000063, 16,Param34000064, 16,Param34000065, 16,Param34000101; Assem4 = "Input Assembly", , , 0x0000, ,, 16,Param34000200, 16,Param34000201, 16,Param34000202; Assem5 = "Output Assembly", , , 0x0000, ,, 16,Param34000250, 16,Param34000251, 16,Param34000252; Assem6 = "Config Assembly", , , 0x0800, ,, 16,Param34000200, 16,Param34000201, 16,Param34000250, 16,Param34000251, 16,Param34000202, 16,Param34000252; [Connection Manager] Object_Name = "Connection Manager Object"; Object_Class_Code = 0x06; Connection1 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x4464040F, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param2000,4,Assem5, $ O->T RPI, size, format Param2000,4,Assem4, $ T->O RPI, size, format ,, $ proxy config size, format 8,Assem6, $ target config size, format "Speed", $ Connection Name "", $ help string "20 04 24 82 2C [Param1000] 2C [Param1001]"; $ Path Connection2 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x4464040F, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param2000,6,Assem5, $ O->T RPI, size, format Param2000,6,Assem4, $ T->O RPI, size, format ,, $ proxy config size, format 12,Assem6, $ target config size, format "Speed & Torque", $ Connection Name "", $ help string "20 04 24 82 2C [Param1002] 2C [Param1003]"; $ Path Connection3 = 0x04010002, $ 0-15 = supported transport classes $ 16 = trigger: cyclic $ 17 = trigger: change of state $ 18 = trigger: application $ 19-23 = trigger: reserved $ 24 = application type: listen-only $ 25 = application type: input-only $ 26 = application type: exclusive-owner $ 27 = application type: redundant-owner $ 28-30 = reserved $ 31 = Direction: Client = 0 / Server = 1 0x4464040F, $ 0 = O->T fixed size supported $ 1 = O->T variable size supported $ 2 = T->O fixed size supported $ 3 = T->O variable size supported $ 4-5 = O->T number of bytes per slot (obsolete) $ 6-7 = T->O number of bytes per slot (obsolete) $ 8-10 = O->T Real time transfer format $ 11 = reserved $ 12-14 = T->O Real time transfer format $ 15 = reserved $ 16 = O->T connection type: NULL $ 17 = O->T connection type: MULTICAST $ 18 = O->T connection type: POINT2POINT $ 19 = O->T connection type: reserved $ 20 = T->O connection type: NULL $ 21 = T->O connection type: MULTICAST $ 22 = T->O connection type: POINT2POINT $ 23 = T->O connection type: reserved $ 24 = O->T priority: LOW $ 25 = O->T priority: HIGH $ 26 = O->T priority: SCHEDULED $ 27 = O->T priority: reserved $ 28 = T->O priority: LOW $ 29 = T->O priority: HIGH $ 30 = T->O priority: SCHEDULED $ 31 = T->O priority: reserved Param2000,,Assem2, $ O->T RPI, size, format Param2000,,Assem1, $ T->O RPI, size, format ,, $ proxy config size, format ,Assem3, $ target config size, format "Custom I/O Connection",$ Connection Name "", $ help string "20 04 24 82 2C 6E 2C 6F"; $ Path [Port] Object_Name = "Port Object"; Object_Class_Code = 0xF4; Port1 = TCP, "Port 1", "20 F5 24 01", 1, 63, ; [Capacity] ConnOverhead = .004; $ Connection Overhead MaxIOConnections = 3; $ Maximum number of Class 1 Connections MaxMsgConnections = 5; $ Maximum number of Class 3 Connections TSpec1 = TxRx, 10, 1400; $ packets per sec @ 10 bytes TSpec2 = TxRx, 100, 1300; $ packets per sec @ 100 bytes TSpec3 = TxRx, 200, 1120; $ packets per sec @ 200 bytes [DLR Class] Revision = 2; Object_Name = "Device Level Ring Object"; Object_Class_Code = 0x47; MaxInst = 1; Number_Of_Static_Instances = 1; Max_Number_Of_Dynamic_Instances = 0; [Ethernet Link Class] Revision = 1; Object_Name = "Ethernet Link Object"; Object_Class_Code = 0xF6; MaxInst = 2; Number_Of_Static_Instances = 2; Max_Number_Of_Dynamic_Instances = 0; Class_Attributes = 2, 3; Instance_Attributes = 1, 2, 3, 6, 7, 8, 9, 10; Class_Services = 0x0E; Instance_Services = 0x0E, 0x10; InterfaceLabel1 = "P1"; InterfaceLabel2 = "P2"; InterfaceType1 = 2; InterfaceType2 = 2;